Limits of use.
- Liquid temperature up to 60 °C.
- Ambient temperature up to 40 °C.
- Manometric suction height up to 7 m.
- Maximum allowable final pressure in the pump casing: 6 bar.
- Continuous duty (S3 60% for three-phase).
Motor
- 2-pole induction motor, 50 Hz (n = 2900 1/min).
- CTM 61: single-phase 230 V ± 10%, with thermal protector.
- Capacitor inserted in terminal box.
- Insulation class F. IP 54 protection.
- Three-phase motors with efficiency class IE2.
- Design according to: EN 60034-1; EN 60335-1, EN 60335-2-41.
70320010000
- BRAND
- CALPEDA
- MATERIAL
- CAST IRON
- POWER (Kw)
- 0,33
- ALIMENTATION (V.)
- 230